Key Features Up to 10 BIB positions per system 8 systems on a network High temperature up to 250ºC 4kW heaters AEC-Q100 lot testing Windows software suite Program database © Abrel Products Limited 2010 Industry Standard The Endzone Burn-in system has been developed for qualification burn-in at temperatures up to 250ºC. The system is extremely flexible, with a 1:1 BIB to driver ratio, allowing for multiple lot testing. Software Windows based software suite Temperature control and profiling PSU setup and sequencing Pattern generation Monitoring and readback Data base management PSU Capability           Low V            Standard V       High V PSU1 0-5V @ 20A   0-20V @ 20A   0-100V @ 3A PSU2 0-5V @ 20A   0-20V @ 20A   0-100V @ 3A PSU3 0-5V @ 20A   0-20V @ 20A   0-100V @ 3A PSU4 0-5V @ 20A   0-20V @ 20A   0-100V @ 3A PSU5 0-5V @ 20A   0-20V @ 20A   0-100V @ 3A VClk   0-5V @ 20A   0-16V @ 20A   0-16V @ 20A Patterns Up to 64 clocks (in 16 clock increments) Maximum frequency 20Mhz 256k min pattern depth Drive voltage 1-16V Drive current 400mA High, Low and Tri-State bit settings 8x8 bit loop counters Monitoring Over Voltage window range 0.1V to 5V Over Voltage Accuracy 1% Under Voltage window range 0.1V to 5V Under Voltage Accuracy 1% Over Current range 0.5A to Max. I of PSU Over Current Accuracy 1% Shutdown options on event failures Temperature Profiling Protocol digital temperature controller LED display and timer control Single, setpoint and profiling program capability Over-temperature control Email info@abrel.com for further information or to request a quotation Mobile System The Mobile Endzone is a PSU and driver board system which can easily dock to an existing HAST or HTOL chamber to provide full dynamic program capability.